例如:"lncRNA", "apoptosis", "WRKY"

Ultrasensitive Electrochemical Detection of miRNA-21 Using a Zinc Finger Protein Specific to DNA-RNA Hybrids.

Anal. Chem.2017 Feb 07;89(3):2024-2031. doi:10.1021/acs.analchem.6b04609. Epub 2017 Jan 06
{{ author.authorName }}{{getOrganisationIndexOf(author)}} {{ author.authorName }}{{getOrganisationIndexOf(author)}}
{{ author.authorName }}{{getOrganisationIndexOf(author)}} {{ author.authorName }}{{getOrganisationIndexOf(author)}}
+ et al

[No authors listed]

Author information
  • {{index+1}} {{ organisation }}

摘要


Both high sensitivity and high specificity are crucial for detection of miRNAs that have emerged as important clinical biomarkers. Just Another Zinc finger proteins (JAZ, ZNF346) bind preferably (but nonsequence-specifically) to DNA-RNA hybrids over single-stranded RNAs, single-stranded DNAs, and double-stranded DNAs. We present an ultrasensitive and highly specific electrochemical method for miRNA-21 detection based on the selective binding of JAZ to the DNA-RNA hybrid formed between a DNA capture probe and a target miRNA-21. This enables us to use chemically stable DNA as a capture probe instead of RNA as well as to apply a standard sandwich-type assay format to miRNA detection. High signal amplification is obtained by (i) enzymatic amplification by alkaline phosphatase (ALP) coupled with (ii) electrochemical-chemical-chemical (ECC) redox cycling involving an ALP product (hydroquinone). Low nonspecific adsorption of ALP-conjugated JAZ is obtained using a polymeric self-assembled-monolayer-modified and casein-treated indium-tin oxide electrode. The detection method can discriminate between target miRNA-21 and nontarget nucleic acids (DNA-DNA hybrid, single-stranded DNA, miRNA-125b, miRNA-155, single-base mismatched miRNA, and three-base mismatched miRNA). The detection limits for miRNA-21 in buffer and 10-fold diluted serum are approximately 2 and 30 fM, respectively, indicating that the detection method is ultrasensitive. This detection method can be readily extended to multiplex detection of miRNAs with only one ALP-conjugated JAZ probe due to its nonsequence-specific binding character. We also believe that the method could offer a promising solution for point-of-care testing of miRNAs in body fluids.

KEYWORDS: {{ getKeywords(articleDetailText.words) }}

基因功能


  • {{$index+1}}.{{ gene }}

图表


原始数据


 保存测序数据
Sample name
Organism Experiment title Sample type Library instrument Attributes
{{attr}}
{{ dataList.sampleTitle }}
{{ dataList.organism }} {{ dataList.expermentTitle }} {{ dataList.sampleType }} {{ dataList.libraryInstrument }} {{ showAttributeName(index,attr,dataList.attributes) }}

文献解读